Air Insulated Metal Enclosed Modular Switchgear

ARME-AIS Serisi 6-12-24 kV Schneider Inside

_

ARME-AIS 36 kV Schneider Inside Metal Mahfazalı Modüler Hücre

_

Air Insulated Metal Enclosed Modular Switchgears can be produced with different brand components if required.

Air Insulated Metal Enclosed Modular Switchgears

Air Insulated Metal Enclosed Modular Switchgears consist of 4 main parts. The safety of these sections is ensured by switching and mechanical locking, and they are isolated from other sections with transitions that provide continuity.

AIR INSULATED MODULE CELL SECTIONS

A- Main Busbar Section

In the Main Busbar Section, there are electrolytic coppers, insulators and bushings selected in accordance with the rated current. Access to this section requires special instructions and safety precautions.

B- Cable Connection Section

Cable Connection Section varies depending on the product type. Available products are as follows:

  • SF6 Gas Circuit Breaker
  • SF6 Gas Load Separator
  • SF6 Gas Separator
  • Voltage Transformer
  • Current Transformer
  • High Voltage Fuse
  • Capacitive Voltage Divider
  • Cable Connection System Equipment

C- Switching (Operating Mechanism) Section

It is the section that allows close maneuvering of switching equipment for opening and closing.

D- Low Voltage Section

This section contains all secondary circuits for control. 

(Dimensions, Protection, Monitoring, Communication and other related systems.)

Maintenance and Control

Armtek “ARME Series” offers more safety and maximum ease of maintenance. The production facilities are ISO-9001 certified, and quality is assured with extensive design and production tests. The low voltage compartment provides sufficient space to easily test and replace internal cables. The independent busbar compartment is structured so that it does not affect any accidents in adjacent panels. Therefore, it does not pose a risk when performing maintenance and control in other sections. Maintenance and control times are minimized due to the easy disassembly and assembly of all equipment.

Security Considerations

Air Insulated Modular Switchgears are designed to prevent explosion or damage to peripheral devices in the event of internal arcing. A high degree of safety for the user and the environment is provided in Air Insulated Modular Switchgears. Short circuit, short-term current and internal arc tests have been tested in accredited certified laboratories in accordance with the IEC 62271-200 standard. It is in IP3X protection class to protect from the external environment.

Security measures are provided against incorrect use and applications thanks to mechanical locking and various precautions. It is not possible to open the cell door without closing the grounding switch and turning the cut-off and disconnectors to the open position. All maneuvers and operations are disabled while the cell door is open.

It is connected with mechanical interlocks between the sections of the cells and with other cells it is related to. The hinge and lock system has a solid structure and is a security wall for faulty operations. The IP observation window on the breaker door allows to see the status of the breaker. The grounding key can be locked in accordance with the isolation and line security. The security of the line as a whole is ensured with communication and signal systems.

Advantages

LSC2A Maximum Service Continuity
Metal partitions grounded between compartments
Maximum human safety with AFL internal arc test feature
Safe against operational errors with electrical and mechanical interlocks
Fast circuit breaking feature and easy maintenance with withdrawable type SF6 Breakers
Continuity in the grounding system
Capacity that can be increased at any time with modular compact design
Tested for short-term resistance 16 kA / 1 s.
Long operating life – 10,000 switching
Easy and safe use designed with all safety measures
After-sales service and spare parts availability 

RELATED STANDARDS 

· LSC2A maximum service continuity
· Metal partitions grounded between compartments
· Maximum human safety with AFL internal arc test feature
· Safe against operational errors with electrical and mechanical interlocks
· Fast circuit breaking feature and easy maintenance with withdrawable type  SF6 Breakers
· Continuity in the grounding system
· Capacity can be increased at any time with modular compact design
· Tested for short-term resistance 16 kA / 1 s.
· Long operating life – 10,000 switching 
· Easy and safe use designed with all safety measures
· After-sales service and spare parts availability